Method Name:
AS002-HS
High Sensitivity
Marketing/Spec:
    TDT Air Scan® is used to quickly and inexpensively identify what compounds are in the air. It utilizes Prism Analytical Technologies, Inc.'s (PATI) widest spectrum, multi-matrix thermal desorption tube that is designed to trap both polar and non-polar compounds. High Sensitivity Air Scan is especially useful for odor investigations since the odor threshold of many compounds is in the parts-per-trillion range. After sampling, the sorption tube is sent to PATI for the qualitative and quantitative identification of over 350 compounds. Other compounds which may be present can also be identified and semi--quantified. TDT Air Scan® is a combination of instrument technology and methodology developed by PATI that has a wide range of applications from personal monitoring, office buildings and warehouses to industrial complexes and landfills.Detection ranges from compounds like formaldehyde, propane, and the freons to 2-methylnaphthalene and tetradecane. Detection limits are in the 100 parts-per-trillion range. Sample collection requires a personal monitoring pump
Features:
  • High sensitivity—25 times more sensitive than regular Air Scan
  • Semi-quantitation of other major compounds not listed in the 350 compound list
  • Encapsulated tubes for long shelf life
  • Easy shipping, handling, and storage
  • Reduced project time by quickly determining what compounds are present as well as what compounds are not present
  • Tubes can be ordered and shipped same day at no additional cost
  • ¼" Diameter tubes are common to personal exposure pumps
  • Data reduction is performed by experienced, degreed chemists
Applications:
  • Monitoring of work place background and exposure levels
  • Personal Exposure Monitoring
  • Sick building syndrome monitoring
  • Process changeover / process maintenance exposure
  • Surveying work areas
  • Odor complaints
Technical
Class of Compounds:
    aldehydes, ketones, esters, alcohols, halogenates, hydrocarbons, aromatics, nitro – nitriles, sulfides, common industrial solvents
MDL:
    10 ng (For Quantitative List A and Semiquantitative List)
Sampling Rate:
    50 to 200 ml/min
Maximum Volume:
    40L
Technical Notes:
    1. One analysis requires that two identical samples be taken
    2. Requires two personal monitoring pumps for sample collection